website statistics

CFAU | Compact Fan Air Ultra

FN-Products-CFA-U_02.jpg

Screenshot 2018-12-10 12.36.42.pngRATED UNDER ASABE S572.1

 Our FANTASTIC range of Ceramic (Alumina) and Delrin® (Acetal Plastic) nozzles are precision moulded in Italy by ASJ Spray-Jet, part of the global ARAG Group. 

logo asj.jpg

INFORMATION

 

NOTICE ON CHANGE OF SQ SPECIFICATION CFAU110015

The Compact Fan Air Ultra has been our main 2,4-D compliant nozzle for 3TS and booms on 25cm spacings due to the smaller sizes, 01, 015 & 02 being VC to a little over 4 BAR.

With a change over in production moulds in late 2020, the CFAU110015 has shifted into the COARSE category making it no longer suitable for 2,4-D application and so we have run out the old CFAU110015 inventory.

We still maintain significant stocks of all the other 2,4-D compliant sizes as per the SQ Transition chart above.

For those requiring a 2,4-D compliant 015 nozzle, we have introduced the NEW Compact Fan Air Tilt (XC). GO TO PAGE HERE!

IN STOCK

CHARTs

#Please note the the CFAU110025 is a new addition to the TFA range. The charts have not quite caught up yet - Dave

 

Screenshot 2018-10-29 14.03.59.png 

 

3TS Settings

 

Below you will see three separate configurations based on the typical 20 km/h 80 lit/ha scenario.

 

A | Where your average travelling speeds are between 15 km/h and 20 km/h, select A. This will ensure your are operating in the optimum pressure range for VC of 3 - 4 BAR, Tier 3. Can be re-configured to COARSE for non 2,4-D applications.

B | Where your average travelling speeds are between 20 km/h and 25 km/h, select B. for optimum 3 - 4 BAR, Tier 3. Can be re-configured to COARSE for non 2,4-D applications.

 

C | Where you have a broad speed range from 15 km/h to 25 km/h and want to cover it optimally, select C. This configuration may appear a bit unusual, however it is based on the fact that the CFAU03, is FULLY VC up to and including 7 BAR, thus as the "main event" in this pair covering a huge range of rate/speed combinations, with the 02 covering very low speed applications.

The added benefit here is that in Tier 3, you'll have a combined 05 allowing for high rate high speed fungicide applications with a C/VC combination when it's needed.

 

Screenshot 2018-10-27 07.12.31.png

Spray Quality classifications are in accordance with ASABE Standard S572.1

ORIGINAL ASJ TECHNICAL SHEETS MAY BE DOWNLOADED FROM EACH OF THE INDIVIDUAL NOZZLE PAGES

 

MINIMUM PRESSURE SETTING

Note that the factory chart show an operating range from 3 BAR, and they should be operated between 3BAR and 4BAR for optimum performance AND 2,4-D VC Compliance. 

For dealing with slowdown for headlands and obstacles, we recommend a 2.5BAR minimum pressure setting.